Analysis of the TMI-2 dome radiation monitor
Abstract
Questions have been raised regarding the accuracy of the in-containment radiation readings from the LOCA qualified, dome radiation monitor, HP-R-214 during the March 28, 1979 accident at the Three Mile Island Unit 2 Reactor. This report discusses the accuracy of the readings, gives the results of examining the radiation monitor itself, and estimates the radiation environment inside containment during the accident.
- Authors:
- Publication Date:
- Research Org.:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- OSTI Identifier:
- 5055194
- Report Number(s):
- GEND-INF-063
ON: TI86002347
- DOE Contract Number:
- AC07-76ID01570
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; THREE MILE ISLAND-2 REACTOR; RADIATION MONITORS; REACTOR ACCIDENTS; CONTAINMENT; ACCIDENTS; ENRICHED URANIUM REACTORS; MEASURING INSTRUMENTS; MONITORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; 220900* - Nuclear Reactor Technology- Reactor Safety; 210200 - Power Reactors, Nonbreeding, Light-Water Moderated, Nonboiling Water Cooled
Citation Formats
Murphy, M B, Mueller, G M, and Jernigan, W C. Analysis of the TMI-2 dome radiation monitor. United States: N. p., 1985.
Web. doi:10.2172/5055194.
Murphy, M B, Mueller, G M, & Jernigan, W C. Analysis of the TMI-2 dome radiation monitor. United States. https://doi.org/10.2172/5055194
Murphy, M B, Mueller, G M, and Jernigan, W C. 1985.
"Analysis of the TMI-2 dome radiation monitor". United States. https://doi.org/10.2172/5055194. https://www.osti.gov/servlets/purl/5055194.
@article{osti_5055194,
title = {Analysis of the TMI-2 dome radiation monitor},
author = {Murphy, M B and Mueller, G M and Jernigan, W C},
abstractNote = {Questions have been raised regarding the accuracy of the in-containment radiation readings from the LOCA qualified, dome radiation monitor, HP-R-214 during the March 28, 1979 accident at the Three Mile Island Unit 2 Reactor. This report discusses the accuracy of the readings, gives the results of examining the radiation monitor itself, and estimates the radiation environment inside containment during the accident.},
doi = {10.2172/5055194},
url = {https://www.osti.gov/biblio/5055194},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Aug 01 00:00:00 EDT 1985},
month = {Thu Aug 01 00:00:00 EDT 1985}
}
Save to My Library