HIGH-TEMPERATURE SENSORS FOR BORAX-V BOILING FUEL RODS
The development of sensors for measurement of temperatures to 2760 deg C in the center of UO/sub 2/-fueled, boiling fuel rods for BORAX-V is discussed. Samples of tantalumsheathed thermocouples with BeO and MgO insulation were tested to failure. Tungsten vs tungsten-26% rhenium was utilized as the thermocouple pair. The first group of thermocouples tested failed at 1650 deg C. Evaluation of 8 other thermocouples showed that the maximum temperature that they can measure accurately is approximately 22OO deg C. The limiting factor is the temperature at which a reaction between BeO and Ta begins. (M.C.G.)
- Research Organization:
- Argonne National Lab., Ill.
- DOE Contract Number:
- W-31-109-ENG-38
- NSA Number:
- NSA-17-015446
- OSTI ID:
- 4748656
- Report Number(s):
- ANL-6636
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-63
- Country of Publication:
- United States
- Language:
- English
Similar Records
RELATIVE THERMAL EXPANSION OF UO$sub 2$ FUEL INPILE. Terminal Report
NUCLEAR ENGINEERING DEPARTMENT, PROGRESS REPORT, SEPTEMBER 1-DECEMBER 31, 1960
RESEARCH AND DEVELOPMENT PROGRAM OF THERMIONIC CONVERSION OF HEAT TO ELECTRICITY. Technical Summary Report
Technical Report
·
Fri Jun 01 00:00:00 EDT 1962
·
OSTI ID:4748656
NUCLEAR ENGINEERING DEPARTMENT, PROGRESS REPORT, SEPTEMBER 1-DECEMBER 31, 1960
Technical Report
·
Mon May 01 00:00:00 EDT 1961
·
OSTI ID:4748656
RESEARCH AND DEVELOPMENT PROGRAM OF THERMIONIC CONVERSION OF HEAT TO ELECTRICITY. Technical Summary Report
Technical Report
·
Fri Aug 30 00:00:00 EDT 1963
·
OSTI ID:4748656