Steam generators secondary side chemical cleaning at Point Lepreau using the Siemens high temperature process
- New Brunswick Power Corp., Lepreau (Canada)
- Siemens AG, Erlangen (Germany)
This paper describes the chemical cleaning of the four steam generators at the Point Lepreau facility, which was accomplished as a part of a normal service outage. The steam generators had been in service for twelve years. Sludge samples showed the main elements were Fe, P and Na, with minor amounts of Ca, Mg, Mn, Cr, Zn, Cl, Cu, Ni, Ti, Si, and Pb, 90% in the form of Magnetite, substantial phosphate, and trace amounts of silicates. The steam generators were experiencing partial blockage of broached holes in the TSPs, and corrosion on tube ODs in the form of pitting and wastage. In addition heat transfer was clearly deteriorating. More than 1000 kg of magnetite and 124 kg of salts were removed from the four steam generators.
- Research Organization:
- CH2M Hill, Gainesville, FL (United States); Argonne National Lab. (ANL), Argonne, IL (United States)
- OSTI ID:
- 467913
- Report Number(s):
- NUREG/CP-0154; ANL-96/14; NEA/CNRA/R-(96)1; CONF-9510423-; ON: TI97004312; TRN: 97:008379
- Resource Relation:
- Conference: CNRA/CSNI workshop on steam generator tube integrity in nuclear power plants, Oak Brook, IL (United States), 30 Oct - 2 Nov 1995; Other Information: PBD: Feb 1997; Related Information: Is Part Of Proceedings of the CNRA/CSNI workshop on steam generator tube integrity in nuclear power plants; Diercks, D.R. [Argonne National Lab., IL (United States)]; PB: 621 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Characterization and dissolution studies of Bruce Unit 3 steam generator secondary side deposits
In-Situ steam generator rebuild performed at Pt. Lepreau generating station