skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Modeled and metered energy savings from exterior wall insulation

Abstract

Millions of single-family masonry (block) houses with slab foundations exist in the southern United States. In fact, approximately 50% of Florida`s six million residences are of concrete block construction. The block walls in these homes are usually uninsulated, and the technology for retrofitting wall insulation is not well developed. Two field tests were performed--one near Phoenix, Arizona and one in Cocoa, Florida--to measure the air-conditioning energy savings and demand reduction impact of applying an exterior insulation and finish system (EEFS) to the exterior of the block wall, and gain practical experience with retrofit application techniques and costs. One field test used a {open_quotes}site-fabricated{close_quotes} insulation system, while the other field test used a commercially available system. The field tests measured a savings of 9% in Arizona and less savings in Florida, and emphasized the impact indoor temperature settings have on cooling energy savings: exterior wall insulation on block homes will produce energy savings in Florida houses only if a low cooling thermostat setting is desirable. The field tests also highlighted an improved comfort benefit from the retrofit - namely, elimination of overheating in rooms with south and west exposures. The DOE-2. ID program was used to analyze the energy savings (air-conditioningmore » and heating) and electric demand impact of applying an EIFS. Air-conditioning energy savings were estimated to be in the range of 8% to 10% in many southern U.S. regions. A 12% savings was predicted for Phoenix, Arizona and a savings of 1% to 4% was predicted for seacoast regions, particularly in Florida. These predictions were in good agreement with the measured values. Peak hour cooling energy savings were predicted to be more uniform throughout the country, generally in the range of %8 to %12.« less

Authors:
; ; ;
Publication Date:
Research Org.:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
279699
Report Number(s):
CONF-9608106-3
ON: DE96013795; TRN: 96:004915
DOE Contract Number:  
AC05-96OR22464
Resource Type:
Conference
Resource Relation:
Conference: 1996 American Council for an Energy-Efficieny Economy (ACEEE) summer study on energy efficiency in buildings, Pacific Grove, CA (United States), 25-31 Aug 1996; Other Information: PBD: Sep 1996
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; WALLS; THERMAL INSULATION; HOUSES; RETROFITTING; AIR CONDITIONING; HEATING; ENERGY CONSUMPTION; POWER DEMAND

Citation Formats

Ternes, M, Parker, D, McLain, H, and Barkaszi, S Jr. Modeled and metered energy savings from exterior wall insulation. United States: N. p., 1996. Web.
Ternes, M, Parker, D, McLain, H, & Barkaszi, S Jr. Modeled and metered energy savings from exterior wall insulation. United States.
Ternes, M, Parker, D, McLain, H, and Barkaszi, S Jr. 1996. "Modeled and metered energy savings from exterior wall insulation". United States. https://www.osti.gov/servlets/purl/279699.
@article{osti_279699,
title = {Modeled and metered energy savings from exterior wall insulation},
author = {Ternes, M and Parker, D and McLain, H and Barkaszi, S Jr},
abstractNote = {Millions of single-family masonry (block) houses with slab foundations exist in the southern United States. In fact, approximately 50% of Florida`s six million residences are of concrete block construction. The block walls in these homes are usually uninsulated, and the technology for retrofitting wall insulation is not well developed. Two field tests were performed--one near Phoenix, Arizona and one in Cocoa, Florida--to measure the air-conditioning energy savings and demand reduction impact of applying an exterior insulation and finish system (EEFS) to the exterior of the block wall, and gain practical experience with retrofit application techniques and costs. One field test used a {open_quotes}site-fabricated{close_quotes} insulation system, while the other field test used a commercially available system. The field tests measured a savings of 9% in Arizona and less savings in Florida, and emphasized the impact indoor temperature settings have on cooling energy savings: exterior wall insulation on block homes will produce energy savings in Florida houses only if a low cooling thermostat setting is desirable. The field tests also highlighted an improved comfort benefit from the retrofit - namely, elimination of overheating in rooms with south and west exposures. The DOE-2. ID program was used to analyze the energy savings (air-conditioning and heating) and electric demand impact of applying an EIFS. Air-conditioning energy savings were estimated to be in the range of 8% to 10% in many southern U.S. regions. A 12% savings was predicted for Phoenix, Arizona and a savings of 1% to 4% was predicted for seacoast regions, particularly in Florida. These predictions were in good agreement with the measured values. Peak hour cooling energy savings were predicted to be more uniform throughout the country, generally in the range of %8 to %12.},
doi = {},
url = {https://www.osti.gov/biblio/279699}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Sep 01 00:00:00 EDT 1996},
month = {Sun Sep 01 00:00:00 EDT 1996}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: