skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: One-way coupled simulation of FIV in a 7-pin wire-wrapped fuel pin bundle

Journal Article · · Nuclear Engineering and Design
 [1]; ORCiD logo [1];  [2];  [3]
  1. Argonne National Lab. (ANL), Argonne, IL (United States)
  2. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  3. Texas A & M Univ., College Station, TX (United States)

A normal fuel geometry found in sodium cooled reactor designs is the hexagonal lattice of wire-wrapped fuel pins. The wire-wrappers, which replace the more common spacer grids, act as a spacer between the fuel pins, while simultaneously increasing the fluid mixing between subchannels. The induced transverse flow, while good for mixing, increases the force load experienced by the fuel pins, increasing the possibility of problematic flow induced vibrations. The primary source of vibrations is turbulent buffeting, so very small in amplitude, but capable of rupturing the fuel cladding by fretting. The vast majority of research on fretting has been for bare rods with spacer grids. There are several significant ways that wire-wrapped fuel pins differ from bare rods that may have significant impact on the vibrations present. The increased transverse flow and asymmetrical flow pattern may result in larger and imbalanced force loads on the pins. The helical bracing of each pin may result in unique vibration patterns, and gaps may form between pins affecting how they are braced. Simulation allows for the observation of the forces present, how the flow field affects these forces, and how the structure responds and can be repeated for multiple cases for relatively low cost. Here, simulation of the flow induced vibrations for a 7-pin wire-wrapped fuel pin bundle is carried out by coupling Nek5000, a spectral element LES/DNS solver with DIABLO, a finite element CSM solver. The small amplitude vibrations allow for the assumption that the structure motion has negligible effect on the fluid flow, permitting the much less computationally expensive one-direction coupling. In order to gather significant force history data for the 2.63 helical pitch structure, a scheme was developed to artificially create force history from the power spectrum density of the one-pitch CFD simulation forces. The vibrations could then be simulated in the structure multiple times varying the contact and gaps between various pins. This provides for the search of worst-case scenarios and informs about the types of fretting that might be present. The simulation geometry is based on an experiment for comparison. However, the viscosity of the simulation was increased by a factor of four to make the simulation computationally feasible. While validation is not possible, comparisons are still valuable.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC52-07NA27344
OSTI ID:
1580471
Report Number(s):
LLNL-JRNL-789261; 969584
Journal Information:
Nuclear Engineering and Design, Vol. 356, Issue C; ISSN 0029-5493
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

Figures / Tables (23)


Similar Records

Particle Image Velocimetry Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle
Journal Article · Fri Jul 01 00:00:00 EDT 2016 · Transactions of the American Nuclear Society · OSTI ID:1580471

Time-Resolved PIV/PTV Measurements on Interior Subchannels of a Wire-Wrapped 61-pin Hexagonal Fuel Bundle
Journal Article · Sat Jul 01 00:00:00 EDT 2017 · Transactions of the American Nuclear Society · OSTI ID:1580471

Wire Wrapped Hexagonal Pin Arrays for PWR Service