Testing of the Piezo-Actuators at High Dynamic Rate Operational Conditions
Conference
·
OSTI ID:1565944
- Fermilab
- Michigan State U.
Reliability of the piezo-actuators deployed in SRF cavity tuners operated at high dynamic voltage range rate conditions can lead to a significant impact on the overall performance of the SRF linacs. We tested at FNAL piezoactuators P-844K075 that were developed at Physik Instrumente (PI) for LCLSII project. Although these actuators were developed for a CW linac we tested them at high dynamic rate inside a cryogenic/insulated vacuum environment. Results of the tests will be presented. Different modes of the piezo-actuators failure will be discussed.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP)
- Contributing Organization:
- PIP-II
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1565944
- Report Number(s):
- FERMILAB-CONF-19-293-TD; oai:inspirehep.net:1754459
- Resource Relation:
- Conference: 18th International Conference on RF Superconductivity (SRF 2019), Dresden, Germany, 06/30-07/05/2019
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mitigation of Dielectric Heating of Piezoelectric Actuators at Cryogenic Temperatures
Review of the Application Piezoelectric Actuators for SRF Cavity Tuners
Operation of an SRF Cavity Tuner Submerged into Liquid Helium
Conference
·
Fri May 20 00:00:00 EDT 2022
· JACoW
·
OSTI ID:1565944
Review of the Application Piezoelectric Actuators for SRF Cavity Tuners
Conference
·
Fri May 20 00:00:00 EDT 2022
· JACoW
·
OSTI ID:1565944
Operation of an SRF Cavity Tuner Submerged into Liquid Helium
Conference
·
Mon Jun 24 00:00:00 EDT 2019
·
OSTI ID:1565944
+6 more