Design of a new main injector cavity for the Fermilab Proton Driver era
Conference
·
OSTI ID:15017201
In the design report of the Fermilab Proton Driver [1], the Main Injector (MI) needs to be upgraded to a 2 MW machine. For the Main Injector radiofrequency (rf) upgrade, R&D efforts are launched to design and build a new rf system. This paper presents the new cavity design study for the rf system. The cavity is simulated with the design code Mafia [2].
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 15017201
- Report Number(s):
- FERMILAB-CONF-05-102-AD; TRN: US200606%%403
- Resource Relation:
- Conference: To appear in the proceedings of Particle Accelerator Conference (PAC 05), Knoxville, Tennessee, 16-20 May 2005
- Country of Publication:
- United States
- Language:
- English