Title: CT Scans of NASA BSTRA Balls 5f5, f2, f3, sr2c, nb2a, hb2b

Technical Report ·
DOI:https://doi.org/10.2172/15009773· OSTI ID:15009773

At the request of Jose Hernandez we performed some feasibility DR/CT scanning of BSTRA Balls of different sizes. To this point we have scanned all the specimens on a single system, HECAT. This particular system employs a 9 meV LINAC as the x-ray source and a THALES 12 x 16 inch 14-bit Amorphous Silicon panel as the detector. In this report we describe the system, detail some of its properties, describe the scans performed and present the data. Figure 1 contains a couple of images of the system as fielded in the 9 MeV bay. The LINAC is in the right portion of the picture. The black panels in the blue frame constitute the High Energy collimator developed specifically for High Energy DR/CT scanning (known here as Stonehenge II). The holes in the collimator panels are beveled to match the distribution of the x-rays from the LINAC, and are sized to just subtend the active area of the THALES Amorphous Silicon panel. Consequently the source to detector distance is restricted to a few positions. Nominally our source to detector distance is 6 meters. The part manipulator, part holder fixturing consists of a translate-rotate assembly on a NEWPORT air bearing table. The stages are NEWPORT RV160PP for rotation and NEWPORT IMS400CC for translation. Both are interfaced through an ESP7000 controller, which is connected to our data acquisition computer over USB. The detector holder also resides on this table and includes pitch, roll and yaw adjustments for aligning the panel to the plane of the rotational table and the x-ray beam. The relatively large source to detector distance and LINAC properties (1 mm spot size) conspire to recommend rotation-only scanning. We use a VARIAN LINATRON 3000 with the small spot retrofit implemented. We have measured the source spot size at about 1 mm. Pixel size on the THALES panel is 0.127 um. Consequently we are in a low-cone angle scanning regime which enables rotation-only 3D CT scanning of objects and assemblies with little ''cone-angle'' error.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
15009773
Report Number(s):
UCRL-TR-202117; TRN: US0406616
Resource Relation:
Other Information: PBD: 29 Jan 2004
Country of Publication:
United States
Language:
English

Similar Records

WE-FG-207A-00: Advances in Dedicated Breast CT
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:15009773

WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:15009773

WE-FG-207A-02: Why We Need Breast CT? - Clinical Perspective
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:15009773