Title: Beamline SRX (05-ID, IVU 21): 25 mA Commissioning Radiation Survey Report

Technical Report ·
DOI:https://doi.org/10.2172/1493230· OSTI ID:1493230
 [1];  [1];  [1];  [1]
  1. Brookhaven National Laboratory (BNL), Upton, NY (United States)

A comprehensive radiological survey of the Beamline SRX (05-ID, In-Vacuum Undulator) was conducted on March 20, 2015 in accordance with the Beamline SRX (05-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 3, 05-ID beamline enclosures (05-ID-A, 05-ID-B and 05-ID-D) and the transport pipe in between 05-ID-A, 05-ID-B and 05-ID-D. Enclosure 05-ID-C currently has only a transport pipe connecting 05-ID-B and 05-ID-D, but will serve as the experimental end station as future branch line for the second IVU. During the surveys the stored beam current varied between 21.04 and 24.87 mA, the 05ID straight section vacuum was around 0.43 ntorr, andfront-end slits opened near their hard stop limits.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
DOE Contract Number:
SC0012704
OSTI ID:
1493230
Report Number(s):
NSLSII-ESH-TN-164; BNL-210985-2019-TECH
Country of Publication:
United States
Language:
English

Similar Records

Beamline IXS (10-ID, IVU 22) 25 mA Commissioning Radiation Survey Report
Technical Report · Tue Mar 10 00:00:00 EDT 2015 · OSTI ID:1493230

Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report
Technical Report · Mon May 18 00:00:00 EDT 2015 · OSTI ID:1493230

Beamline CHX (11-ID, IVU 20): 25 mA Commissioning Radiation Survey Report
Technical Report · Tue Apr 14 00:00:00 EDT 2015 · OSTI ID:1493230

Related Subjects