Title: Comparison of Analytical Shielding Calculations for NSLS-II Linac Lateral Wall with FLUKA Monte-Carlo Program

Technical Report ·
DOI:https://doi.org/10.2172/1493212· OSTI ID:1493212
 [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)

The bulk shielding for NSLS II accelerator enclosures has been designed to reduce the dose rates to less than 0.5 mrem/h at the occupied regions during normal operation. The lateral wall for Linac enclosure is designed to protect personnel from the transverse radiation. The current Linac lateral wall is composed of 1 m concrete, based on the analytical calculations using Swansons’ thick target approximation [1]. The dose rate calculations with current Linac lateral shielding (general area and penetrations) have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the analytical calculation [1]. The dose rates calculated by SHIELD11 [2] program for limited cases have also been included in this technical note.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
DOE Contract Number:
SC0012704
OSTI ID:
1493212
Report Number(s):
NSLSII-ESH-TN-133; BNL-210967-2019-TECH
Country of Publication:
United States
Language:
English

Similar Records

Comparison of Analytical Calculations for NSLS-II Booster Bulk Shielding with FLUKA Monte-Carlo Program
Technical Report · Fri Oct 04 00:00:00 EDT 2013 · OSTI ID:1493212

Shielding NSLS-II light source: Importance of geometry for calculating radiation levels from beam losses [Shielding Synchrotron Light Sources: Importance of geometry for calculating radiation levels from beam losses]
Journal Article · Wed Aug 10 00:00:00 EDT 2016 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1493212

Comparison of the MCNP6 and FLUKA Codes in Shielding Calculation at ProNova Proton Therapy Facility
Journal Article · Fri Jul 01 00:00:00 EDT 2016 · Transactions of the American Nuclear Society · OSTI ID:1493212

Related Subjects