The Stanford 2 GeV electron-positron storage ring is equipped with 20 beam position monitors. The principle of beam coupling is analysed and a calculation is made here for the sensitivity to beam current and position, as well as for the intrinsic distortion of this type of monitor. Beam orbit coordinates are reconstructed by scanning the monitor's four electrode signals and the 20 stations around the machine. Normalization of the data and electronics nonlinearity compensation are one of the routine tasks of the computer control system.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
US Atomic Energy Commission (AEC)
Grant/Contract Number:
AC02-76SF00515
OSTI ID:
1442833
Report Number(s):
SLAC-PUB-1227; TRN: US1900929
Journal Information:
Nuclear Instruments and Methods, Vol. 113, Issue 3; ISSN 0029-554X
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

Figures / Tables (16)


Similar Records

The beam positions of the SPEAR storage ring
Journal Article · Sat Dec 01 00:00:00 EST 1973 · Nuclear Instruments and Methods · OSTI ID:1442833

Commissioning results of the narrow-band beam position monitor system upgrade in the APS storage ring.
Conference · Tue Apr 20 00:00:00 EDT 1999 · OSTI ID:1442833

Beam position measurement in the photon factory storage ring
Conference · Mon Aug 01 00:00:00 EDT 1983 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:1442833