Polymer encapsulated microcavity optomechanical magnetometer
Journal Article
·
· Scientific Reports
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Washington Univ., St. Louis, MO (United States)
We demonstrate a magnetometer using polymer encapsulated whispering-gallery-mode microcavity actuated by a micro-magnet. The magnetic field induces force on the micro-magnet causing deformation in the polymer around the microcavity. Subsequently the microcavity detects the change in the refractive index of the polymer resulted from the deformation. This magnetometer works in the frequency range of hertz-to-kilohertz range and achieves a sensitivity of 880 pT/Hz1/2 at 200 Hz in a micro-scale sensor volume. Polymer encapsulation of the magnetometer and fiber optical connection ensures environmental robustness and practicality of the sensor.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE
- Grant/Contract Number:
- AC52-06NA25396
- OSTI ID:
- 1396126
- Report Number(s):
- LA-UR-17-22375
- Journal Information:
- Scientific Reports, Vol. 7, Issue 1; ISSN 2045-2322
- Publisher:
- Nature Publishing GroupCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Cited by: 30 works
Citation information provided by
Web of Science
Web of Science
Quantum enhanced optomechanical magnetometry
|
journal | January 2018 |
Quantum enhanced optomechanical magnetometry | text | January 2018 |
Multi-Parameter Sensing in a Multimode Self-Interference Micro-Ring Resonator by Machine Learning
|
journal | January 2020 |
Invited Article: Scalable high-sensitivity optomechanical magnetometers on a chip
|
journal | December 2018 |
Whispering Gallery Modes at THz
|
journal | September 2019 |
Wireless whispering-gallery-mode sensor for thermal sensing and aerial mapping
|
journal | September 2018 |
Similar Records
Ring microlasers from conducting polymers
Erbium-implanted high-Q silica toroidal microcavity laser on a silicon chip
Diamond magnetometer enhanced by ferrite flux concentrators
Journal Article
·
Fri Aug 01 00:00:00 EDT 1997
· Physical Review, B: Condensed Matter
·
OSTI ID:1396126
+1 more
Erbium-implanted high-Q silica toroidal microcavity laser on a silicon chip
Journal Article
·
Wed Sep 01 00:00:00 EDT 2004
· Physical Review. A
·
OSTI ID:1396126
+3 more
Diamond magnetometer enhanced by ferrite flux concentrators
Journal Article
·
Wed Jun 24 00:00:00 EDT 2020
· Physical Review Research
·
OSTI ID:1396126
+6 more