Title: Hot Cell Installation and Demonstration of the Severe Accident Test Station

Technical Report ·
DOI:https://doi.org/10.2172/1394377· OSTI ID:1394377
 [1];  [1];  [1];  [1]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

A Severe Accident Test Station (SATS) capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident (DBA) and beyond design basis accident (BDBA) scenarios has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory (IFEL), a hot cell facility at Oak Ridge National Laboratory. The two test station modules provide various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident (LOCA) testing, defueled oxidation quench testing and high temperature BDBA testing. The installation of the SATS system restores the domestic capability to examine postulated and extended LOCA conditions on spent fuel and cladding and provides a platform for evaluation of advanced fuel and accident tolerant fuel (ATF) cladding concepts. This document reports on the successful in-cell demonstration testing of unirradiated Zircaloy-4. It also contains descriptions of the integral test facility capabilities, installation activities, and out-of-cell benchmark testing to calibrate and optimize the system.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1394377
Report Number(s):
ORNL/TM-2017/434
Country of Publication:
United States
Language:
English

Similar Records

Severe Accident Test Station Design Document
Technical Report · Tue Sep 01 00:00:00 EDT 2015 · OSTI ID:1394377

Length Dependence of Severe Accident Test Station Integral Testing
Technical Report · Sun Sep 01 00:00:00 EDT 2019 · OSTI ID:1394377

Steam Oxidation and Burst Testing in the Severe Accident Test Station
Technical Report · Sun Jul 01 00:00:00 EDT 2018 · OSTI ID:1394377