Title: Enhanced gamma ray sensitivity in bismuth triiodide sensors through volumetric defect control

Journal Article · · Applied Physics Letters
DOI:https://doi.org/10.1063/1.4962293· OSTI ID:1366970

In some of the more attractive semiconducting compounds for ambient temperature radiation detector applications are impacted by low charge collection efficiency due to the presence of point and volumetric defects. This has been particularly true in the case of BiI3, which features very attractive properties (density, atomic number, band gap, etc.) to serve as a gamma ray detector, but has yet to demonstrate its full potential. Here, we show that by applying growth techniques tailored to reduce defects, the spectral performance of this promising semiconductor can be realized. Gamma ray spectra from >100 keV source emissions are now obtained from high quality Sb:BiI3 bulk crystals with limited concentrations of defects (point and extended). The spectra acquired in these high quality crystals feature photopeaks with resolution of 2.2% at 662 keV. Infrared microscopy is used to compare the local microstructure between radiation sensitive and non-responsive crystals. Our work demonstrates that BiI3 can be prepared in melt-grown detector-grade samples with superior quality and can acquire the spectra from a variety of gamma ray sources.

Research Organization:
Univ. of Michigan, Ann Arbor, MI (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Nonproliferation and Verification Research and Development (NA-22); USDOE
Grant/Contract Number:
NA0002534; NE0000730
OSTI ID:
1366970
Alternate ID(s):
OSTI ID: 1315848
Journal Information:
Applied Physics Letters, Vol. 109, Issue 9; ISSN 0003-6951
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 14 works
Citation information provided by
Web of Science

References (23)

Band gap and structure of single crystal BiI 3 : Resolving discrepancies in literature journal July 2013
Extended Defects in CdZnTe Radiation Detectors journal August 2009
Synchrotron radiation studies of spectral response features caused by Te inclusions in a large volume coplanar grid CdZnTe detector
  • Hansson, C. C. T.; Owens, A.; Quarati, F.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 695 https://doi.org/10.1016/j.nima.2011.10.021
journal December 2012
Bismuth Tri-Iodide Polycrystalline Films for Digital X-Ray Radiography Applications journal February 2004
Wide-bandgap compound semiconductors for X- or gamma-ray detectors journal December 2011
Defect Engineering of BiI 3 Single Crystals: Enhanced Electrical and Radiation Performance for Room Temperature Gamma-Ray Detection journal January 2014
Bismuth tri-iodide crystal for nuclear radiation detectors journal October 2002
Fabrication and testing of antimony doped bismuth tri-iodide semiconductor gamma-ray detectors journal August 2016
Growth, fabrication, and testing of bismuth tri-iodide semiconductor radiation detectors journal March 2015
Bismuth iodide crystals as a detector material: some optical and electrical properties
  • Dmitriyev, Yuriy N.; Bennett, Paul R.; Cirignano, Leonard J.
  • SPIE's International Symposium on Optical Science, Engineering, and Instrumentation, SPIE Proceedings https://doi.org/10.1117/12.366625
conference October 1999
Hole trapping and infrared quenching of photoconductivity in HgI2 crystals journal October 1975
CBRN Protection book January 2013
Zum Mechanismus des lichtelektrischen Prim�rstromes in isolierenden Kristallen journal March 1932
BiI3 single crystal for room-temperature gamma ray detectors
  • Saito, T.; Iwasaki, T.; Kurosawa, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 806 https://doi.org/10.1016/j.nima.2015.10.036
journal January 2016
Spectroscopy on thick HgI/sub 2/ detectors: a comparison between planar and pixelated electrodes journal August 2003
Long-term stability of 1-cm thick pixelated HgI/sub 2/ gamma-ray spectrometers operating at room temperature journal August 2004
Fabrication of high-performance CdZnTe quasi-hemispherical gamma-ray CAPture plus detectors conference August 2006
A method for suppressing polarization phenomena in TlBr detectors
  • Hitomi, Keitaro; Shoji, Tadayoshi; Niizeki, Yoshio
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 585, Issue 1-2 https://doi.org/10.1016/j.nima.2007.11.012
journal January 2008
Charge loss between contacts of CdZnTe pixel detectors
  • Bolotnikov, A. E.; Cook, W. R.; Harrison, F. A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 432, Issue 2-3 https://doi.org/10.1016/S0168-9002(99)00388-5
journal August 1999
CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
  • Eisen, Y.; Shor, A.; Mardor, I.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 428, Issue 1 https://doi.org/10.1016/S0168-9002(99)00003-0
journal June 1999
Fityk : a general-purpose peak fitting program journal September 2010
Superheating suppresses structural disorder in layered BiI3 semiconductors grown by the Bridgman method journal January 2016
Characterization of bismuth tri-iodide single crystals for wide band-gap semiconductor radiation detectors
  • Lintereur, Azaree T.; Qiu, Wei; Nino, Juan C.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 652, Issue 1 https://doi.org/10.1016/j.nima.2010.12.013
journal October 2011

Cited By (4)

Dopant compensation in alloyed CH3NH3PbBr3−xClx perovskite single crystals for gamma-ray spectroscopy journal July 2017
The electronic structure and band interface of cesium bismuth iodide on a titania heterostructure using hard X-ray spectroscopy journal January 2018
Room temperature semiconductor detectors for nuclear security journal July 2019
Dopant compensation in alloyed CH3NH3PbBr3-xClx perovskite single crystals for gamma-ray spectroscopy text January 2017

Similar Records

Enhanced gamma ray sensitivity in bismuth triiodide sensors through volumetric defect control
Journal Article · Mon Aug 29 00:00:00 EDT 2016 · Applied Physics Letters · OSTI ID:1366970

BiI3 Crystals for High Energy Resolution Gamma-Ray Spectroscopy
Technical Report · Wed Apr 12 00:00:00 EDT 2017 · OSTI ID:1366970

Fabrication and testing of antimony doped bismuth tri-iodide semiconductor gamma-ray detectors
Journal Article · Wed Apr 13 00:00:00 EDT 2016 · Radiation Measurements · OSTI ID:1366970