Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
- Univ. of Washington, Seattle, WA (United States)
- Cornell Univ., Ithaca, NY (United States)
- Lab. Nazionali Frascati dell'INFN, Frascati (Italy); Istituto Nazionale di Ottica del C.N.R., Pisa (Italy)
- Lab. Nazionali Frascati dell'INFN, Frascati (Italy)
- INFN, Napoli (Italy); Univ. di Napoli, Napoli (Italy)
- INFN, Napoli (Italy)
- James Madison Univ., Harrisonburg, VA (United States)
- Univ. of Kentucky, Lexington, KY (United States)
- Univ. of Virginia, Charlottesville, VA (United States)
Here, we have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. As a result, the performance is documented in a series of bench and beam tests.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Cornell Univ., Ithaca, NY (United States); SLAC National Accelerator Laboratory (SLAC), Menlo Park, CA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP)
- Grant/Contract Number:
- AC02-07CH11359; SC0008037
- OSTI ID:
- 1347130
- Alternate ID(s):
- OSTI ID: 1908535
- Report Number(s):
- FERMILAB-PUB-16-516-E-PPD; arXiv:1611.03180; 1496973
- Journal Information:
- Journal of Instrumentation, Vol. 12, Issue 01; ISSN 1748-0221
- Publisher:
- Institute of Physics (IOP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Web of Science
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs
|
journal | July 2016 |
The Brookhaven muon storage ring magnet
|
journal | January 2001 |
The calibration system of the new g−2 experiment at Fermilab
|
journal | July 2016 |
Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
|
journal | May 2015 |
Geiger-mode avalanche photodiodes, history, properties and problems
|
journal | November 2006 |
Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment
|
journal | January 2017 |
Electro-optical characterization of SiPM: A comparative study
|
journal | October 2009 |
Modelling a silicon photomultiplier (SiPM) as a signal source for optimum front-end design
|
journal | March 2007 |
Simulation of Silicon Photomultiplier Signals
|
journal | December 2009 |
Muon anomalous magnetic moment in the standard model extension
|
journal | December 2017 |
Timing and characterization of shaped pulses with MHz ADCs in a detector system: a comparative study and deep learning approach
|
journal | March 2019 |
Similar Records
Detection of high energy muons with sub-20 ps timing resolution using L(Y)SO crystals and SiPM readout
Novel 4x4 SiPM Array Readout with Integrated Preamplification Stage, Optimized for the PWO Detectors of the EIC EEEMCal [Slides]