The purpose of this Standard Operating Procedure (SOP) is to give guidelines on how to measure the volume of a container for use in radiography studies. This SOP gives details on a recommended method of how exactly to measure the volume of containers used for specimens for Micro CT and EDS measurements. This volume is important in determining accurate densities of the specimens. This SOP is referred to in TP 48 - Preparation of Hydrogen Peroxide/Icing Sugar Specimens for X-ray Measurements by J.G. Reynolds and H.E. Martz