skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Limiting Magnitude, τ, teff, and Image Quality in DES Year 1

Technical Report ·
DOI:https://doi.org/10.2172/1250877· OSTI ID:1250877
 [1];  [2];  [3]
  1. Univ. of Pennsylvania, Philadelphia, PA (United States)
  2. Univ. of Illinois, Urbana-Champaign, IL (United States). National Center for Supercomputing Applications (NCSA)
  3. Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

The Dark Energy Survey (DES) is an astronomical imaging survey being completed with the DECam imager on the Blanco telescope at CTIO. After each night of observing, the DES data management (DM) group performs an initial processing of that night's data, and uses the results to determine which exposures are of acceptable quality, and which need to be repeated. The primary measure by which we declare an image of acceptable quality is $$\tau$$, a scaling of the exposure time. This is the scale factor that needs to be applied to the open shutter time to reach the same photometric signal to noise ratio for faint point sources under a set of canonical good conditions. These conditions are defined to be seeing resulting in a PSF full width at half maximum (FWHM) of 0.9" and a pre-defined sky brightness which approximates the zenith sky brightness under fully dark conditions. Point source limiting magnitude and signal to noise should therefore vary with t in the same way they vary with exposure time. Measurements of point sources and $$\tau$$ in the first year of DES data confirm that they do. In the context of DES, the symbol $$t_{eff}$$ and the expression "effective exposure time" usually refer to the scaling factor, $$\tau$$, rather than the actual effective exposure time; the "effective exposure time" in this case refers to the effective duration of one second, rather than the effective duration of an exposure.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
1250877
Report Number(s):
FERMILAB-TM-2610-AE-CD; 1450750
Country of Publication:
United States
Language:
English

Similar Records

Deep drilling in the time domain with DECam: survey characterization
Journal Article · Mon Nov 21 00:00:00 EST 2022 · Monthly Notices of the Royal Astronomical Society · OSTI ID:1250877

The Dark Energy Survey and Operations: Year 6 – The Finale
Technical Report · Thu Jan 30 00:00:00 EST 2020 · OSTI ID:1250877

Optical follow-up of gravitational wave triggers with DECam
Journal Article · Sun Oct 01 00:00:00 EDT 2017 · Journal of Physics. Conference Series · OSTI ID:1250877