Title: Wall-Friction Support of Vertical Loads in Submerged Sand and Gravel Columns

Technical Report ·
DOI:https://doi.org/10.2172/1234608· OSTI ID:1234608
 [1];  [1];  [1]
  1. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

Laboratory studies of the ‘floor-loads’ under submerged vertical columns of sand and/or gravel indicate that such loads can be approximated by a buoyancy-corrected Janssen-silo-theory-like relationship. Similar to conditions in storage silos filled with dry granular solids, most of the weight of the sand or gravel is supported by wall friction forces. Laboratory measurements of the loads on the floor at the base of the water-filled columns (up to 25-diameters tall) indicate that the extra floor-load from the addition of the granular solid never exceeded the load that would exist under an unsupported (wide) bed of submerged sand or gravel that has a total depth corresponding to only two column-diameters. The measured floorloads reached an asymptotic maximum value when the depth of granular material in the columns was only three or four pipe-diameters, and never increased further as the columns were filled to the top (e.g. up to heights of 10 to 25 diameters). The floor-loads were stable and remained the same for days after filling. Aggressive tapping (e.g. hitting the containing pipe on the outside, manually with a wrench up and down the height and around the circumference) could increase (and occasionally decrease) the floor load substantially, but there was no sudden collapse or slumping to a state without significant wall friction effects. Considerable effort was required, repeatedly tapping over almost the entire column wall periphery, in order to produce floor-loads that corresponded to the total buoyancy-corrected weight of granular material added to the columns. Projecting the observed laboratory behavior to field conditions would imply that a stable floor-load condition, with only a slightly higher total floor pressure than the preexisting hydrostatic-head, would exist after a water-filled bore-hole is filled with sand or gravel. Significant seismic vibration (either a large nearby event or many micro-seismic events over an extended period) would likely be necessary before the full (buoyancy-corrected) weight of the sand and/or gravel would be ‘delivered’ to the bottom of the submerged column.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC52-07NA27344
OSTI ID:
1234608
Report Number(s):
LLNL-TR-676586
Country of Publication:
United States
Language:
English

Similar Records

Remote Technology to Retrieve Waste Below the 324 Building at the Hanford Site - 19622
Conference · Mon Jul 01 00:00:00 EDT 2019 · OSTI ID:1234608

THERMAL MODELING ANALYSIS OF CST MEDIA IN THE SMALL COLUMN ION EXCHANGE PROJECT
Technical Report · Mon Nov 01 00:00:00 EDT 2010 · OSTI ID:1234608

EC Driver - 41" Stroke Hydraulic Cylinder
Technical Report · Thu May 24 00:00:00 EDT 1990 · OSTI ID:1234608

Related Subjects