Conceptual MEIC electron ring injection scheme using CEBAF as a full energy injector
- Jefferson Lab., Newport News, VA (United States)
The Medium-energy Electron-Ion Collider (MEIC) proposed by Jefferson Lab is planning to use the newly upgraded 12 GeV CEBAF 1497 MHz SRF CW recirculating linac as a full-energy injector for the electron collider ring. The electron collider ring is proposed to reuse the 476 MHz PEP-II RF system to achieve high installed voltage and high beam power. The MEIC electron injection requires 3-10 (or 12) GeV beam in 3-4µs long bunch trains with low duty factor and high peak current, resulting in strong transient beam loading for the CEBAF. In this paper, we propose an injection scheme that can match the two systems' frequencies with acceptable injection time, and also address the transient beam loading issue in CEBAF. The scheme is compatible with future upgrade to 952.6 MHz SRF system in the electron ring.
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Nuclear Physics (NP)
- DOE Contract Number:
- AC05-06OR23177
- OSTI ID:
- 1221906
- Report Number(s):
- JLAB-ACC-15-2081; DOE/OR/23177-3421; TRN: US1601456
- Resource Relation:
- Conference: IPAC 2015, Richmond, VA (United States), 3-8 May 2015
- Country of Publication:
- United States
- Language:
- English
Similar Records
Capture, acceleration and bunching rf systems for the MEIC booster and storage rings
Science Requirements and Conceptual Design for a Polarized Medium Energy Electron-Ion Collider at Jlab