Duct Leakage Repeatability Testing
Abstract
The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.
- Authors:
-
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- Publication Date:
- Research Org.:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- Sponsoring Org.:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- OSTI Identifier:
- 1220535
- Report Number(s):
- LBNL-175563
7155
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- lbnl, duct leakage
Citation Formats
Walker, Iain, and Sherman, Max. Duct Leakage Repeatability Testing. United States: N. p., 2014.
Web. doi:10.2172/1220535.
Walker, Iain, & Sherman, Max. Duct Leakage Repeatability Testing. United States. https://doi.org/10.2172/1220535
Walker, Iain, and Sherman, Max. 2014.
"Duct Leakage Repeatability Testing". United States. https://doi.org/10.2172/1220535. https://www.osti.gov/servlets/purl/1220535.
@article{osti_1220535,
title = {Duct Leakage Repeatability Testing},
author = {Walker, Iain and Sherman, Max},
abstractNote = {The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.},
doi = {10.2172/1220535},
url = {https://www.osti.gov/biblio/1220535},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Aug 01 00:00:00 EDT 2014},
month = {Fri Aug 01 00:00:00 EDT 2014}
}