Field Testing of Compartmentalization Methods for Multifamily Construction
- Building Science Corporation, Westford, MA (United States)
The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).
- Research Organization:
- Building Science Corporation, Westford, MA (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1220431
- Report Number(s):
- DOE/GO-102015-4559; 7034
- Country of Publication:
- United States
- Language:
- English
Similar Records
Field Testing of Compartmentalization Methods for Multifamily Construction
Building America Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction (Fact Sheet)
Related Subjects
residential
Residential Buildings
BSC
Building America
Building Science Corporation
multifamily
comparmentaliation
blower door
blower door testing
air leakage
guarded testing
guarded leakage
nulling
demising wall
area separation wall
fire-resistance rated assembly
fire-resistance rated wall
UL U347
fire wall
rated assembly
rated assemblies