skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Case Study of Envelope Sealing in Existing Multiunit Structures

Technical Report ·
DOI:https://doi.org/10.2172/1219796· OSTI ID:1219796

This report describes envelope air sealing that was included in the retrofit of a 244 unit low-rise multifamily housing complex in Durham, N.C. On average, total leakage was reduced by nearly half, from 19.7 ACH50 to 9.4 ACH50. Important air leakage locations identified included plumbing and electrical penetrations, dropped ceilings/soffits, windows, ducts and wall-to-floor intersections. Specifications and a pictorial guide were developed for contractors performing the work.

Research Organization:
ARIES Collaborative, New York, NY (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
DOE Contract Number:
AC36-08GO28308; KNDJ-0-40347-00
OSTI ID:
1219796
Report Number(s):
DOE/GO-102012-3583; 5969
Country of Publication:
United States
Language:
English