Title: Results for Actinide Removal Process 512-S Guard Filter Analyses

Technical Report ·
DOI:https://doi.org/10.2172/1177480· OSTI ID:1177480
 [1];  [1];  [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

The Actinide Removal Process (ARP) removes Sr and actinides by adsorption to monosodium titanate (MST) from radioactive salt solutions that have been stored at the Savannah River Site (SRS). The MST solids are then removed by filtration. Material from the 512-S Late Wash Precipitate Tank (LWPT) is cross-flow filtered and the filtrate sent through a secondary filter (guard filter) to the Late Wash Hold Tank (LWHT) for further processing in the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU).