skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Absolute beam emittance measurements at RHIC using ionization profile monitors

Abstract

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

Authors:
 [1];  [1];  [1];  [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1154892
Report Number(s):
BNL-105970-2014-IR; BNL-C-A/AP/522
R&D Project: KBCH139; KB0202011; TRN: US1500116
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; BROOKHAVEN RHIC; IONIZATION CHAMBERS; BEAM EMITTANCE; DATA COVARIANCES; COMPARATIVE EVALUATIONS; FUNCTIONS; ACCURACY; POLARIMETERS; BEAM PROFILES; BEAM MONITORS; relativistic heavy ion collider

Citation Formats

Minty, M., Connolly, R, Liu, C., Summers, T., and Tepikian, S. Absolute beam emittance measurements at RHIC using ionization profile monitors. United States: N. p., 2014. Web. doi:10.2172/1154892.
Minty, M., Connolly, R, Liu, C., Summers, T., & Tepikian, S. Absolute beam emittance measurements at RHIC using ionization profile monitors. United States. https://doi.org/10.2172/1154892
Minty, M., Connolly, R, Liu, C., Summers, T., and Tepikian, S. 2014. "Absolute beam emittance measurements at RHIC using ionization profile monitors". United States. https://doi.org/10.2172/1154892. https://www.osti.gov/servlets/purl/1154892.
@article{osti_1154892,
title = {Absolute beam emittance measurements at RHIC using ionization profile monitors},
author = {Minty, M. and Connolly, R and Liu, C. and Summers, T. and Tepikian, S.},
abstractNote = {In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.},
doi = {10.2172/1154892},
url = {https://www.osti.gov/biblio/1154892}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Aug 15 00:00:00 EDT 2014},
month = {Fri Aug 15 00:00:00 EDT 2014}
}