We obtain the half aperture for the circulating beam by scaling from the high beta quads, which have B=400 m and half aperture $$\bar{ha}$$=60 mm. Therefore: ha ≥ 60√β/400 mm. This rule neglects dispersive effects (ηp) but this is acceptable.