Injection and Beam Dumping for RHIC (Recap of RHIC Meeting Dated 31 July 85)
- Brookhaven National Lab. (BNL), Upton, NY (United States)
We obtain the half aperture for the circulating beam by scaling from the high beta quads, which have B=400 m and half aperture $$\bar{ha}$$=60 mm. Therefore: ha ≥ 60√β/400 mm. This rule neglects dispersive effects (ηp) but this is acceptable.