Title: SPES-2, AP600 intergral system test S01007 2 inch CL to core make-up tank pressure balance line break

Technical Report ·
DOI:https://doi.org/10.2172/111438· OSTI ID:111438
; ;  [1]
  1. SIET S.p.A. Piacenza (Italy); and others

The SPES-2 is a full height, full pressure experimental test facility reproducing the Westinghouse AP600 reactor with a scaling factor of 1/395. The experimental plant, designed and operated by SIET in Piacenza, consists of a full simulation of the AP600 primary core cooling system including all the passive and active safety systems. In 1992, Westinghouse, in cooperation with ENEL (Ente Nazionale per l` Energia Elettrica), ENEA (Enter per le numove Technlogie, l` Energia e l` Ambient), Siet (Societa Informazioni Esperienze Termoidraulich) and ANSALDO developed an experimental program to test the integrated behaviour of the AP600 passive safety systems. The SPES-2 test matrix, concluded in November 1994, has examined the AP600 passive safety system response for a range of small break LOCAs at different locations on the primary system and on the passive system lines; single steam generator tube ruptures with passive and active safety systems and a main steam line break transient to demonstrate the boration capability of passive safety systems for rapid cooldown. Each of the tests has provided detailed experimental results for verification of the capability of the analysis methods to predict the integrated passive safety system behaviour. Cold and hot shakedown tests have been performed on the facility to check the characteristics of the plant before starting the experimental campaign. The paper first presents a description of the SPES-2 test facility then the main results of S01007 test {open_quotes}2{close_quotes} Cold Leg (CL) to Core Make-up Tank (CMT) pressure balance line break{close_quotes} are reported and compared with predictions performed using RELAP5/mod3/80 obtained by ANSALDO through agreement with U.S.N.R.C. (U.S. Nuclear Regulatory Commission). The SPES-2 nodalization and all the calculations here presented were performed by ANSALDO and sponsored by ENEL as a part of pre-test predictions for SPES-2.

Research Organization:
US Nuclear Regulatory Commission (NRC), Washington, DC (United States). Div. of Systems Technology; American Nuclear Society (ANS), La Grange Park, IL (United States); American Institute of Chemical Engineers, New York, NY (United States); American Society of Mechanical Engineers (ASME), New York, NY (United States); Canadian Nuclear Society, Toronto, ON (Canada); European Nuclear Society (ENS), Bern (Switzerland); Atomic Energy Society of Japan, Tokyo (Japan); Japan Society of Multiphase Flow, Kyoto (Japan)
OSTI ID:
111438
Report Number(s):
NUREG/CP-0142-Vol.4; CONF-950904-Vol.4; ON: TI95017080; TRN: 95:021626
Resource Relation:
Conference: 7. international topical meeting on nuclear reactor thermal-hydraulics (Nureth-7), Saratoga Springs, NY (United States), 10-15 Sep 1995; Other Information: PBD: Sep 1995; Related Information: Is Part Of Proceedings of the 7th International Meeting on Nuclear Reactor Thermal-Hydraulics NURETH-7. Sessions 17-24; Block, R.C.; Feiner, F. [American Nuclear Society, La Grange Park, IL (United States)]; PB: 825 p.
Country of Publication:
United States
Language:
English