Title: Rapid depressurization event analysis in BWR/6 using RELAP5 and contain

Conference ·
OSTI ID:107768
;  [1]
  1. Pennsylvania State Univ., University Park, PA (United States)

Noncondensable gases may become dissolved in Boiling Water Reactor (BWR) water level instrumentation during normal operations. Any dissolved noncondensable gases inside these water columns may come out of solution during rapid depressurization events, and displace water from the reference leg piping resulting in a false high level. These water level errors may cause a delay or failure in actuation, or premature shutdown of the Emergency Core Cooling System. (ECCS). If a rapid depressurization causes an erroneously high water level, preventing automatic ECCS actuation, it becomes important to determine if there would be other adequate indications for operator response and other signals for automatic actuation such as high drywell pressure. It is also important to determine the effect of the level signal on ECCS operation after it is being actuated. The objective of this study is to determine the detailed coupled containment/NSSS response during this rapid depressurization events in BWR/6. The selected scenarios involve: (a) inadvertent opening of all ADS valves, (b) design basis (DB) large break loss of coolant accident (LOCA), and (c) main steam line break (MSLB). The transient behaviors are evaluated in terms of: (a) vessel pressure and collapsed water level response, (b) specific transient boundary conditions, (e.g., scram, MSIV closure timing, feedwater flow, and break blowdown rates), (c) ECCS initiation timing, (d) impact of operator actions, (e) whether indications besides low-low water level were available. The results of the analysis had shown that there would be signals to actuate ECCS other than low reactor level, such as high drywell pressure, low vessel pressure, high suppression pool temperature, and that the plant operators would have significant indications to actuate ECCS.

Research Organization:
US Nuclear Regulatory Commission (NRC), Washington, DC (United States). Div. of Systems Technology; American Nuclear Society (ANS), La Grange Park, IL (United States); American Institute of Chemical Engineers, New York, NY (United States); American Society of Mechanical Engineers (ASME), New York, NY (United States); Canadian Nuclear Society, Toronto, ON (Canada); European Nuclear Society (ENS), Bern (Switzerland); Atomic Energy Society of Japan, Tokyo (Japan); Japan Society of Multiphase Flow, Kyoto (Japan)
OSTI ID:
107768
Report Number(s):
NUREG/CP-0142-Vol.2; CONF-950904-Vol.2; ON: TI95017078; CNN: Contract RS-NRR-93-027; TRN: 95:021390
Resource Relation:
Conference: 7. international topical meeting on nuclear reactor thermal-hydraulics (Nureth-7), Saratoga Springs, NY (United States), 10-15 Sep 1995; Other Information: PBD: Sep 1995; Related Information: Is Part Of Proceedings of the 7th International Meeting on Nuclear Reactor Thermal-Hydraulics NURETH-7. Volume 2, Sessions 6-11; Block, R.C.; Feiner, F. [comps.] [American Nuclear Society, La Grange Park, IL (United States)]; PB: 795 p.
Country of Publication:
United States
Language:
English

Similar Records

Best-estimate coupled RELAP/CONTAIN analysis of inadvertent BWR ADS valve opening transient
Conference · Fri Jan 01 00:00:00 EST 1993 · Transactions of the American Nuclear Society; (United States) · OSTI ID:107768

Reactivity transients during a blowdown in a MSIV closure ATWS
Conference · Fri Jan 01 00:00:00 EST 1988 · Transactions of the American Nuclear Society; (USA) · OSTI ID:107768

Evaluation of Potential to Air Ingestion From RWT Following RAS
Conference · Sat Jul 01 00:00:00 EDT 2006 · OSTI ID:107768