skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: What Have we Learned from the LCLS Injector?

Technical Report ·
DOI:https://doi.org/10.2172/1036973· OSTI ID:1036973

The LCLS injector reliably delivered a high quality electron beam since it started operations three years ago. Some initial commissioning results were described in Ref. [1]. This note is to summarize what we have understood from the LCLS injector including drive laser, cathode, RF gun, injector beam line elements, beam modeling and operations. What we have learned during the LCLS injector commissioning and operation has lead to modified specifications for the UV drive laser system. A flat temporal profile originally required in the LCLS design is not necessary to achieve a low emittance electron beam for the LCLS operations. According to our recent studies, a laser pulse with 3 ps Gaussian temporal profile (FWHM) can achieve a similar emittance compared to a flat temporal profile laser. The sensitivity of the emittance to the laser pulse length at 250 pC of bunch charge was studied, as shown in Figure 1. Only slight variations were observed for both projected and time-sliced emittances with laser pulses from 2.2 ps to 4.5 ps FWHM. Space charge forces certainly become weak but RF emittance which is proportional to the bunch length square increases due to the longer laser pulse. Thus, the projected emittance optimum may be a trade-off between space charge forces and RF emittance, while the time-sliced emittance determined by space charge forces may be slightly improved with a longer laser pulse length. Simulations and theory also show that spatial Gaussian-cut laser profile produces a better emittance compared to uniform profiles due to increased linearity of the space charge forces. Preliminary experimental data show that the emittance with a Gaussian-cut is almost as good as the one with uniform although not better than. In addition, the laser transmission through the iris for spatial Gaussian-cut is about twice the one for spatial uniform. More experimental studies with the new Coherent laser system are needed to make a more solid conclusion.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515
OSTI ID:
1036973
Report Number(s):
SLAC-PUB-14644; TRN: US201207%%378
Country of Publication:
United States
Language:
English

Similar Records

Emittance Measurements from a Laser Driven Electron Injector
Technical Report · Mon Jul 28 00:00:00 EDT 2003 · OSTI ID:1036973

Emittance Measurements from a Laser Driven Electron Injector [Thesis]
Technical Report · Fri Jan 01 00:00:00 EST 1999 · OSTI ID:1036973

Status of the R& D Program at the Gun Test Facility
Technical Report · Wed Jan 12 00:00:00 EST 2005 · OSTI ID:1036973