Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts
Abstract
This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces.
- Authors:
- Publication Date:
- Research Org.:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Org.:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- OSTI Identifier:
- 1029856
- Report Number(s):
- NREL/SR-5500-52825; DOE/GO-102011-3421
KNDJ-0-40339-00; TRN: US201201%%240
- DOE Contract Number:
- AC36-08GO28308
- Resource Type:
- Technical Report
- Resource Relation:
- Related Information: Work performed by Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, Florida
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; AIR QUALITY; ARCHITECTS; ATTICS; BUILDERS; COMMUNICATIONS; CONSTRUCTION; CONTRACTORS; DESIGN; DUCTS; ENERGY EFFICIENCY; IMPLEMENTATION; INDOORS; MARKET; MARKETERS; PLANNING; PLUMBING; RECOMMENDATIONS; VERIFICATION; Building America; HVAC; duct systems; indoor air quality
Citation Formats
Beal, D., McIlvaine, J., Fonorow, K., and Martin, E. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts. United States: N. p., 2011.
Web. doi:10.2172/1029856.
Beal, D., McIlvaine, J., Fonorow, K., & Martin, E. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts. United States. https://doi.org/10.2172/1029856
Beal, D., McIlvaine, J., Fonorow, K., and Martin, E. 2011.
"Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts". United States. https://doi.org/10.2172/1029856. https://www.osti.gov/servlets/purl/1029856.
@article{osti_1029856,
title = {Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts},
author = {Beal, D. and McIlvaine, J. and Fonorow, K. and Martin, E.},
abstractNote = {This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces.},
doi = {10.2172/1029856},
url = {https://www.osti.gov/biblio/1029856},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Nov 01 00:00:00 EDT 2011},
month = {Tue Nov 01 00:00:00 EDT 2011}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.