Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method
A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.
- Research Organization:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- Sponsoring Organization:
- Accelerator& Fusion Research Division
- DOE Contract Number:
- DE-AC02-05CH11231
- OSTI ID:
- 1022724
- Report Number(s):
- LBNL-4639E; TRN: US1104469
- Resource Relation:
- Conference: PAC 11
- Country of Publication:
- United States
- Language:
- English
Similar Records
Progress in ETA-II magnetic field alignment using stretched wire and low energy electron beam techniques
NDCX-II project commencing at LBNL