skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Ferrocyanide safety program: Thermal analysis of ferrocyanide tanks, Group I

Technical Report ·
DOI:https://doi.org/10.2172/10173367· OSTI ID:10173367

The purpose of this report is to document the results of a series of analyses conducted to the heat loads of the first of two groups of tanks on the Ferrocyanide Watch List. The analyses use the fill/transfer history with a transient solution for the heat load determination. Nominal values of the heat load are determined, as well as the upper lower bounds of the heat load. Ranges of thermal conductivity of the tank waste are determined.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
10173367
Report Number(s):
WHC-EP-0729; ON: DE94016478; BR: 35AF11201/35AF11202; TRN: 94:015607
Resource Relation:
Other Information: PBD: Jun 1994
Country of Publication:
United States
Language:
English