Title: Improving the action requirements of technical specifications: A risk-comparison of continued operation and plant shutdown

Conference ·
OSTI ID:10121203
;  [1];  [1]
  1. Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

When the systems needed to remove decay heat are inoperable or degraded, the risk of shutting down the plant may be comparable to, or even higher than, that of continuing power operation with the equipment inoperable while giving priority to repairs. This concern arises because the plant may not have sufficient capability for removing decay heat during the shutdown. However, Technical Specifications (TSs) often require ``immediate`` shutdown of the plant. In this paper, the authors present risk-based analyses of the various operational policy alternatives available in such situations, with an example application to the standby service water (SSW) system of a BWR. These analyses can be used to define risk-effective requirements for those standby safety systems under discussion.