Factors Affecting Indoor Air Concentrations of Volatile Organic Compounds at a Site of Subsurface Gasoline Contamination
We report a field study of soil gas transport of volatile organic compounds (VOCs) into a slab-on-grade building found at a site contaminated with gasoline. Although the high VOC concentrations (30-60 g m{sup -3}) measured in the soil gas at depths of 0.7 m below the building suggest a potential for high levels of indoor VOC, the measured indoor air concentrations were lower than those in the soil gas by approximately six orders of magnitude ({approx} 0.03 mg m{sup -3}). This large ratio is explained by (1) the expected dilution of soil gas entering the building via ambient building ventilation (a factor of {approx}1000), and (2) an unexpectedly sharp gradient in soil gas VOC concentration between the depths of 0.1 and 0.7 m (a factor of {approx}1000). Measurements of the soil physical and biological characteristics indicate that a partial physical barrier to vertical transport in combination with microbial degradation provides a likely explanation for this gradient. These factors are likely to be important to varying degrees at other sites.
- Research Organization:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
- Sponsoring Organization:
- Environmental Energy Technologies Division
- DOE Contract Number:
- DE-AC02-05CH11231
- OSTI ID:
- 1009822
- Report Number(s):
- LBL-37768; ESTHAG; TRN: US201109%%325
- Journal Information:
- Environmental Science and Technology, Vol. 30, Issue 10; Related Information: Journal Publication Date: 1996; ISSN 0013-936X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Understanding the origin of radon indoors: Building a predictive capability
Prediction of risk-based screening levels for infiltration of volatile subsurface contaminants into buildings