ANALOG FRONT-END ELECTRONICS FOR BEAM POSITION MEASUREMENT ON THE BEAM HALO MEASUREMENT
Enhancements have been made to the log-ratio analog front-end electronics based on the Analog Devices 8307 logarithmic amplifier as used on the LEDA accelerator. The dynamic range of greater than 85 dB, has been extended to nearly the full capability of the AD8307 from the previous design of approximately 65 dB through the addition of a 350 MHz band-pass filter, careful use of ground and power plane placement, signal routing, and power supply bypassing. Additionally, selection of high-isolation RF switches (55dB) has been an integral part of a new calibration technique, which is fully described in another paper submitted to this conference. Provision has also been made for insertion of a first-stage low-noise amplifier for using the circuit under low-signal conditions.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 783248
- Report Number(s):
- LA-UR-01-3217; TRN: US0108485
- Resource Relation:
- Journal Volume: 2; Conference: Conference title not supplied, Conference location not supplied, Conference dates not supplied; Other Information: PBD: 1 Jun 2001
- Country of Publication:
- United States
- Language:
- English
Similar Records
BPM ANALOG FRONT-END ELECTRONICS BASED ON THE AD8307 LOG AMPLIFIER
The Logarithmic Beam Position Monitor