skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Axial tomography from digitized real time radiography

Conference ·
OSTI ID:5960303

Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

Research Organization:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Organization:
U.S. Department of Energy (DOE)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5960303
Report Number(s):
UCRL-92005; CONF-850533-1; ON: DE85006767; TRN: 85-008051
Resource Relation:
Conference: 6. symposium on X- and gamma-ray sources and applications, Ann Arbor, MI, USA, 21 May 1985
Country of Publication:
United States
Language:
English