skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

Technical Report ·
DOI:https://doi.org/10.2172/1260915· OSTI ID:1260915
 [1];  [1];  [1];  [1];  [1];  [1]
  1. Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States)

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

Research Organization:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy Building Technologies Program
DOE Contract Number:
AC36-08GO28308
OSTI ID:
1260915
Report Number(s):
NREL/SR-5500-58714; DOE/GO-102013-3943
Country of Publication:
United States
Language:
English