Draft evaluation of the frequency for gas sampling for the high burnup confirmatory data project
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
This report fulfills the M3 milestone M3FT-15SN0802041, “Draft Evaluation of the Frequency for Gas Sampling for the High Burn-up Storage Demonstration Project” under Work Package FT-15SN080204, “ST Field Demonstration Support – SNL”. This report provides a technically based gas sampling frequency strategy for the High Burnup (HBU) Confirmatory Data Project. The evaluation of: 1) the types and magnitudes of gases that could be present in the project cask and, 2) the degradation mechanisms that could change gas compositions culminates in an adaptive gas sampling frequency strategy. This adaptive strategy is compared against the sampling frequency that has been developed based on operational considerations. Gas sampling will provide information on the presence of residual water (and byproducts associated with its reactions and decomposition) and breach of cladding, which could inform the decision of when to open the project cask.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE Office of Nuclear Energy (NE), Fuel Cycle Technologies (NE-5)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1235985
- Report Number(s):
- SAND-2015-4449R; 599113
- Country of Publication:
- United States
- Language:
- English
Similar Records
Sister Rod Nondestructive Examination Final Report
Evaluation of the Frequencies for Canister Inspections for SCC