skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

Journal Article · · Optical Engineering
 [1];  [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. As a result, using the closed-form solution, we propose a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC04-94AL85000
OSTI ID:
1235334
Report Number(s):
SAND-2015-3823J; 583959
Journal Information:
Optical Engineering, Vol. 54, Issue 7; ISSN 0091-3286
Publisher:
SPIECopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 8 works
Citation information provided by
Web of Science

References (10)

Differences of digital camera resolution metrology to describe noise reduction artifacts conference January 2010
Digital camera resolution measurement using sinusoidal Siemens stars conference February 2007
Performance assessment of compressive sensing imaging conference May 2014
Evaluation of mobile phone camera benchmarking using objective camera speed and image quality metrics journal July 2014
Evaluating the quality of EDOF in camera phones conference January 2010
Fiber-optic raster scanning two-photon endomicroscope using a tubular piezoelectric actuator journal June 2014
A quantitative performance measure for a clinical evaluation of comb structure removal algorithms in flexible endoscopy conference April 2008
Practice-oriented evaluation of lateral resolution for micro- and nanometre measurement techniques journal May 2009
Iterative reconstruction of projection images from a microlens-based optical detector journal January 2011
Evaluating digital cameras conference February 2006

Cited By (1)


Figures / Tables (11)