Title: Various Recrystallizations of CL-20 (HNIW hexanitrohexaazaisowurtzitane).

Technical Report ·
DOI:https://doi.org/10.2172/1227343· OSTI ID:1227343
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc., shown in Figure 1. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1cm increments, though 1cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Positive results were detected visually or audibly by the operator as smoke, flash, report, charring/tearing of the sandpaper, etc.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1227343
Report Number(s):
SAND2015-10378R; 614040
Country of Publication:
United States
Language:
English

Similar Records

80% Hydrogen Peroxide Mixtures with Various Fuels
Technical Report · Tue Oct 01 00:00:00 EDT 2013 · OSTI ID:1227343

Small-Scale Sensitivity Testing (SSST) Report
Technical Report · Wed Apr 06 00:00:00 EDT 2016 · OSTI ID:1227343

Phase stability of {epsilon} and {gamma} HNIW (CL-20) at high-pressure and temperature
Journal Article · Wed Dec 12 00:00:00 EST 2007 · AIP Conference Proceedings · OSTI ID:1227343

Related Subjects