CALiPER Report 21.1. Linear (T8) Lamps in a 2x4 K12-Lensed Troffer
This report focuses on the performance of the same 31 linear LED lamps operated in a typical troffer with a K12 prismatic lens. In general, luminaire efficacy is strongly dictated by lamp efficacy, but the optical system of the luminaire substantially reduces the differences between the luminous intensity distributions of the lamps. While the distributions in the luminaire are similar, the differences remain large enough that workplane illuminance uniformity may be reduced if linear LED lamps with a narrow distribution are used. At the same time, linear LED lamps with a narrower distribution result in slightly higher luminaire efficiency.
- Research Organization:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Solid-State Lighting)
- OSTI ID:
- 1221103
- Report Number(s):
- PNNL-SA-23246; 6820
- Country of Publication:
- United States
- Language:
- English
Similar Records
CALiPER Report 21.2. Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers
DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers
Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report
Technical Report
·
Thu May 01 00:00:00 EDT 2014
·
OSTI ID:1221103
DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers
Technical Report
·
Tue May 20 00:00:00 EDT 2014
·
OSTI ID:1221103
+2 more
Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report
Technical Report
·
Fri Jan 16 00:00:00 EST 2009
·
OSTI ID:1221103