Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs
Abstract
This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.
- Authors:
-
- Building Science Corporation, Westford, MA (United States)
- Publication Date:
- Research Org.:
- Building Science Corporation, Westford, MA (United States)
- Sponsoring Org.:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- OSTI Identifier:
- 1220467
- Report Number(s):
- DOE/GO-102015-4632
7080
- DOE Contract Number:
- AC36-08GO28308
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; residential; Residential Buildings; BSC; Building America; Deep Energy Retrofit; Deep Energy Enclosure Retrofit; Enclosure Retrofit; retrofit; Flat Roof
Citation Formats
Loomis, H., and Pettit, B. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs. United States: N. p., 2015.
Web. doi:10.2172/1220467.
Loomis, H., & Pettit, B. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs. United States. https://doi.org/10.2172/1220467
Loomis, H., and Pettit, B. 2015.
"Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs". United States. https://doi.org/10.2172/1220467. https://www.osti.gov/servlets/purl/1220467.
@article{osti_1220467,
title = {Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs},
author = {Loomis, H. and Pettit, B.},
abstractNote = {This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.},
doi = {10.2172/1220467},
url = {https://www.osti.gov/biblio/1220467},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri May 01 00:00:00 EDT 2015},
month = {Fri May 01 00:00:00 EDT 2015}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.