skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: C-14/I-29 Preservation and Hold Time Survey

Technical Report ·
DOI:https://doi.org/10.2172/1177886· OSTI ID:1177886
 [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

Preservation and hold time of radionuclides must account for both nuclear half-lives and nonnuclear loss mechanisms, but variations in the latter are often neglected. Metals-based defaults are inappropriate for long-lived non-metals C-14 and I-129, which are vulnerable to chemical and biological volatilization. Non-acidification is already widely practiced for them. Recommended addition measures from radiological and chemical literature include glass containers where possible, water filtration where possible, headspace minimization, light shielding, cold (4°C) storage and unfiltered water hold time of 28 days. Soil hold time may need to be shortened when water-logged, excessively sandy, or still adjusting to significant new contamination.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC09-08SR22470
OSTI ID:
1177886
Report Number(s):
SRNS-J2000-2015-00232
Country of Publication:
United States
Language:
English