Title: VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES

Abstract

SRNL’s validation of ANSI N42.34-D6 for the Domestic Nuclear Detection Office (DNDO) was performed utilizing one hand-held instrument (or RID) – the FLIR identiFINDER 2. Each section of the standard was evaluated via a walk-through or test. NOTE: In Table 1, W = walk-through and T = test, as directed by the Domestic Nuclear Detection Office (DNDO). For a walk-through, the experiment was either setup or reviewed for setup; for a test, the N42.34-D6 procedures were followed with some exceptions and comments noted. SRNL is not fully able to evaluate a RID against Sections 7 (Environmental), 8 (Electromagnetic), and 9 (Mechanical) of N42.34, so those portions of this validation were done in collaboration with Qualtest, Inc. in Orlando, Florida. The walk-throughs and tests of Sections 7, 8, and 9 were performed in Qualtest, Inc. facilities with SRNL providing radiological sources as necessary. Where applicable, assessment results and findings of the walk-throughs and tests were recorded on datasheets and a validation summary is provided. A general comment pertained to test requirements found in another standard and referenced in N42.34-D6. For example, step 1 of the test method in section 8.1.2 states “RF test set up information can be found in IECmore » 61000-4-3.” It is recommended that any information from other standards necessary for conducting the tests within N42.34 should be posted in N42.34 for simplicity and to prevent the user from having to peruse other documents. Another general comment, as noted by Qualtest, is that a tolerance reference is not listed for each test in sections 7-9. Overall, the N42.34-D6 was proven to be practicable, but areas for improvement and recommendations were identified for consideration prior to final ballot submittal.« less

Authors:
Publication Date:
Research Org.:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1154716
Report Number(s):
SRNL-STI-2014-00360
DOE Contract Number:  
DE-AC09-08SR22470
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY

Citation Formats

Lorier, T. VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES. United States: N. p., 2014. Web. doi:10.2172/1154716.
Lorier, T. VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES. United States. https://doi.org/10.2172/1154716
Lorier, T. 2014. "VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES". United States. https://doi.org/10.2172/1154716. https://www.osti.gov/servlets/purl/1154716.
@article{osti_1154716,
title = {VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES},
author = {Lorier, T.},
abstractNote = {SRNL’s validation of ANSI N42.34-D6 for the Domestic Nuclear Detection Office (DNDO) was performed utilizing one hand-held instrument (or RID) – the FLIR identiFINDER 2. Each section of the standard was evaluated via a walk-through or test. NOTE: In Table 1, W = walk-through and T = test, as directed by the Domestic Nuclear Detection Office (DNDO). For a walk-through, the experiment was either setup or reviewed for setup; for a test, the N42.34-D6 procedures were followed with some exceptions and comments noted. SRNL is not fully able to evaluate a RID against Sections 7 (Environmental), 8 (Electromagnetic), and 9 (Mechanical) of N42.34, so those portions of this validation were done in collaboration with Qualtest, Inc. in Orlando, Florida. The walk-throughs and tests of Sections 7, 8, and 9 were performed in Qualtest, Inc. facilities with SRNL providing radiological sources as necessary. Where applicable, assessment results and findings of the walk-throughs and tests were recorded on datasheets and a validation summary is provided. A general comment pertained to test requirements found in another standard and referenced in N42.34-D6. For example, step 1 of the test method in section 8.1.2 states “RF test set up information can be found in IEC 61000-4-3.” It is recommended that any information from other standards necessary for conducting the tests within N42.34 should be posted in N42.34 for simplicity and to prevent the user from having to peruse other documents. Another general comment, as noted by Qualtest, is that a tolerance reference is not listed for each test in sections 7-9. Overall, the N42.34-D6 was proven to be practicable, but areas for improvement and recommendations were identified for consideration prior to final ballot submittal.},
doi = {10.2172/1154716},
url = {https://www.osti.gov/biblio/1154716}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Sep 03 00:00:00 EDT 2014},