Transient thermal analysis for radioactive liquid mixing operations in a large-scaled tank
- Savannah River Site Nuclear Solutions, LLC, Aiken, SC (United States). Savannah River National Lab. (SRNL)
A transient heat balance model was developed to assess the impact of a Submersible Mixer Pump (SMP) on radioactive liquid temperature during the process of waste mixing and removal for the high-level radioactive materials stored in Savannah River Site (SRS) tanks. The model results will be mainly used to determine the SMP design impacts on the waste tank temperature during operations and to develop a specification for a new SMP design to replace existing longshaft mixer pumps used during waste removal. The present model was benchmarked against the test data obtained by the tank measurement to examine the quantitative thermal response of the tank and to establish the reference conditions of the operating variables under no SMP operation. The results showed that the model predictions agreed with the test data of the waste temperatures within about 10%.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE
- Grant/Contract Number:
- AC09-08SR22470
- OSTI ID:
- 1135788
- Alternate ID(s):
- OSTI ID: 1556583
- Report Number(s):
- SRNL-STI-2014-00273; TRN: US1600481
- Journal Information:
- Nuclear Engineering and Design, Vol. 277; ISSN 0029-5493
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English