skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: System Study: High-Pressure Coolant Injection 1998-2012

Abstract

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

Authors:
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1129946
Report Number(s):
INL/EXT-14-31125
DOE Contract Number:  
DE-AC07-05ID14517
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; coolant injection; operating experience

Citation Formats

Wierman, T. E. System Study: High-Pressure Coolant Injection 1998-2012. United States: N. p., 2013. Web. doi:10.2172/1129946.
Wierman, T. E. System Study: High-Pressure Coolant Injection 1998-2012. United States. https://doi.org/10.2172/1129946
Wierman, T. E. 2013. "System Study: High-Pressure Coolant Injection 1998-2012". United States. https://doi.org/10.2172/1129946. https://www.osti.gov/servlets/purl/1129946.
@article{osti_1129946,
title = {System Study: High-Pressure Coolant Injection 1998-2012},
author = {Wierman, T. E.},
abstractNote = {This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.},
doi = {10.2172/1129946},
url = {https://www.osti.gov/biblio/1129946}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Oct 01 00:00:00 EDT 2013},
month = {Tue Oct 01 00:00:00 EDT 2013}
}