  1. Electrical breakdown dynamics in an argon bubble submerged in conductive liquid for nanosecond pulsed discharges

    Abstract This study delves into the dynamics of cold atmospheric plasma and their interaction within conductive solutions under the unique conditions of nanosecond pulsed discharges (22 kV peak voltage, 10 ns FWHM, 4.5 kV ns −1 rate-of-rise). The research focuses on the electrical response, breakdown, and discharge propagation in an argon bubble, submerged in a NaCl solution of varying conductivity. Full or partial discharges were observed at conductivities of 1.5 µ S cm −1 (deionized water) to 1.6 mS cm −1 , but no breakdown was observed at 11.0 mS cm −1 when reducing the electrode gap. It is demonstrated that at higher conductivitymore » electric breakdown is observed only when the gas bubble comes into direct contact with the electrode and multiple emission nodes were observed at different timescales. These nodes expanded in the central region of the bubble over timescales longer than the initial high-voltage pulse. This work offers a temporal resolution of 2 ns exposure times over the first 30 ns of the initial voltage pulse, and insight into plasma formation over decaying reflected voltage oscillations over 200 ns.« less
  2. Data-driven prediction of the output composition of an atmospheric pressure plasma jet

    Cold atmospheric plasma (CAP) in open air hosts numerous chemical species engaged in thousands of chemical reactions. Comprehensive diagnosis of its chemical composition is important across various fields from medicine, where reactive oxygen and nitrogen play key roles, to surface modification. In applications, a centimeter-scale helium–air jet operates for minutes, featuring micrometer-sized streamers and an atmospheric pressure-induced collision frequency in the hundreds of GHz range. To address this intricate multi-scale issue, we introduce a machine learning approach: using a physics-informed neural network (PINN) to tackle the multi-scale complexities inherent in predicting the complete list of species concentrations, gas temperature, andmore » electron temperature of a CAP jet supplied with a mixture of helium and air. Experimental measurements of O3, N2O, and NO2 concentrations downstream of the plasma jet, combined with fundamental physics laws, the conservation of mass and charge, constrain the PINN, enabling it to predict the concentrations of all species that are not available from the experiment, along with gas and electron temperatures. The results, therefore, obey all the physical laws we provided and can have a chemical balance with the measured concentrations. In conclusion, this methodology holds promise for describing and potentially regulating complex systems with limited experimental datasets.« less
  3. Electric discharge initiation in water with gas bubbles: A time scale approach

    High voltage nanosecond pulse driven electric discharges in de-ionized water with an argon bubble suspended between two electrodes were experimentally investigated. Two electrode configurations were used to temporally resolve the time scales of the discharge from the applied voltage rise time (7 ns), through the end of the first pulse (∼30 ns), and longer (>50 ns). We found that, in positive and negative applied voltage polarities, discharge initiates in the water at the tip of the anode. The discharge in the water rapidly extends (∼104 m/s) to the apex of the bubble and light emitted from inside the bubble begins to form. The steepmore » rate of rise of the applied voltage (dV/dt<4 kV/ns) and the short time for the development of discharge in the water suggest that cavitation is a likely mechanism for discharge initiation and propagation in water. In addition, the short duration of the applied voltage pulse results in only a partial Townsend discharge inside the bubble.« less
  4. Moderate pressure plasma source of nonthermal electrons

    Plasma sources of electrons offer control of gas and surface chemistry without the need for complex vacuum systems. The plasma electron source presented here is based on a cold cathode glow discharge (GD) operating in a dc steady state mode in a moderate pressure range of 2–10 torr. Ion-induced secondary electron emission is the source of electrons accelerated to high energies in the cathode sheath potential. The source geometry is a key to the availability and the extraction of the nonthermal portion of the electron population. The source consists of a flat and a cylindrical electrode, 1 mm apart. Ourmore » estimates show that the length of the cathode sheath in the plasma source is commensurate (~0.5–1 mm) with the inter-electrode distance so the GD operates in an obstructed regime without a positive column. Estimations of the electron energy relaxation confirm the non-local nature of this GD, hence the nonthermal portion of the electron population is available for extraction outside of the source. The use of a cylindrical anode presents a simple and promising method of extracting the high energy portion of the electron population. Langmuir probe measurements and optical emission spectroscopy confirm the presence of electrons with energies ~15 eV outside of the source. These electrons become available for surface modification and radical production outside of the source. In conclusion, the extraction of the electrons of specific energies by varying the anode geometry opens exciting opportunities for future exploration.« less
  5. Unstable behavior of anodic arc discharge for synthesis of nanomaterials

    A short carbon arc operating with a high ablation rate of the graphite anode exhibits a combined motion of the arc and the arc attachment to the anode. A characteristic time scale of this motion is in a 10-3 sec range. The arc exhibits a negative differential resistance before the arc motion occurs. Thermal processes in the arc plasma region interacting with the ablating anode are considered as possible causes of this unstable arc behavior. It is also hypothesized that the arc motion could potentially cause mixing of the various nanoparticles synthesized in the arc in the high ablation regime.