skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information
  1. Rapid determination of supercritical CO2 and brine relative permeability using an unsteady-state flow method

    In this study, relative permeability of supercritical CO2 (scCO2) and brine was determined in reactive and non-reactive rock cores using a combination of unsteady-state methodology and computed tomography. Experiments were conducted using a medical grade CT scanner to determine saturation using a custom Python script. The saturation and differential pressure across the core were then used to derive four empirical constants to calculate relative permeability. This methodology increases temporal efficiency while reducing experimental complexity. Additionally, we show that the method can be used to determine scCO2 relative permeability in a wide range of lithologies and flow rates, and with themore » ability to account for matrix dissolution during scCO2 flooding.« less
  2. Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

    The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginiamore » University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.« less

Search for:
Keywords
10.18141/1438190

Refine by:
Resource Type
Availability
Author / Contributor
Research Organization