Passive Standoff Detection of RDX Residues on Metal Surfaces via Infrared Hyperspectral Imaging
Journal Article
·
· Analytical and Bioanalytical Chemistry, 395(2):337-348
Hyperspectral images of galvanized steel plates, each containing a stain of RDX, were recorded using a commercial longwave infrared imaging spectrometer. Demonstrations of passive RDX chemical detection at areal dosages between 16 and 90 µg / cm2 were carried out over practical stand-off ranges between 14 and 50 m. Efforts to develop better chemical anomaly and target detection through chemometric analyses are described.
- Research Organization:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 985009
- Report Number(s):
- PNNL-SA-64981; ISSN 1618-2650; TRN: US201016%%1707
- Journal Information:
- Analytical and Bioanalytical Chemistry, 395(2):337-348, Vol. 395, Issue 2; ISSN 1618-2642
- Country of Publication:
- United States
- Language:
- English
Similar Records
Passive Infrared Hyperspectral Imaging for Standoff Detection of Tetryl Explosive Residue on a Steel Surface
Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging
Simultaneous standoff plume detection using a swept-ECQCL and passive hyperspectral imaging
Conference
·
Tue Jun 15 00:00:00 EDT 2010
·
OSTI ID:985009
Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging
Journal Article
·
Fri Aug 05 00:00:00 EDT 2022
· Remote Sensing
·
OSTI ID:985009
+1 more
Simultaneous standoff plume detection using a swept-ECQCL and passive hyperspectral imaging
Conference
·
Mon Sep 12 00:00:00 EDT 2022
·
OSTI ID:985009