Title: Report of the Error and Emittance Task Force on the superconducting super collider: Part 1, Resistive machines

A review of the design and specifications of the resistive accelerators in the SSC complex was conducted during the past year. This review was initiated in response to a request from the SSC Project Manager. The Error and Emittance Task Force was created October 30, 1992, and charged with reviewing issues associated with the specification of errors and tolerances throughout the injector chain and in the Collider, and to optimize the global error budget. Effects which directly impact the emittance budget were of prime importance. The Task Force responded to three charges: Examination of the resistive accelerators and their injection and extraction systems; examination of the connecting beamlines and the overall approach taken in their design; and global filling, timing, and synchronization issues. The High Energy Booster and the Collider were deemed to be sufficiently different from the resistive accelerators that it was decided to treat them as a separate group. They will be the subject of a second part to this report.
Publication Date:
OSTI Identifier:
93538
Report Number(s):
SSCL-SR--1226
ON: DE95011166; TRN: 95:018419
DOE Contract Number:
AC35-89ER40486
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: Oct 1993
Research Org:
Superconducting Super Collider Lab., Waxahachie, TX (United States)
Sponsoring Org:
USDOE, Washington, DC (United States)
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; SUPERCONDUCTING SUPER COLLIDER; BEAM EMITTANCE; ERRORS; DESIGN; PARTICLE BOOSTERS; BEAM TRANSPORT; LINEAR ACCELERATORS; BEAM INJECTION; BEAM EXTRACTION