Title: Advanced Overfire Air system and design

Technical Report ·
DOI:https://doi.org/10.2172/828246· OSTI ID:828246

The objective of the proposed project is to design, install and optimize a prototype advanced tangential OFA air system on two mass feed stoker boilers that can burn coal, biomass and a mixture of these fuels. The results will be used to develop a generalized methodology for retrofit designs and optimization of advanced OFA air systems. The advanced OFA system will reduce particulate and NOx emissions and improve overall efficiency by reducing carbon in the ash and excess oxygen. The advanced OFA will also provide capabilities for carrying full load and improved load following and transitional operations.

Research Organization:
Golden Field Office, Golden, CO (US)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EE) (US)
DOE Contract Number:
FG36-01GO11029
OSTI ID:
828246
Report Number(s):
DE-FG36-01GO11029; TRN: US200430%%1056
Resource Relation:
Other Information: PBD: 30 Jul 2004
Country of Publication:
United States
Language:
English

Similar Records

Optimization of low-NO{sub x} overfire air systems to improve boiler performance
Technical Report · Wed May 01 00:00:00 EDT 1996 · OSTI ID:828246

Hybrid coal gasification
Journal Article · Mon Jan 15 00:00:00 EST 2007 · Power Engineering (Barrington) · OSTI ID:828246

The application of combustion diagnostics to low NO{sub x} overfire air systems